Eurotron Instruments UK Limited
UniGas 3000+ -
DownLoad Unigas 3000 Hand Book
UniGas 3000+ is a multigas compact hand-
A third cell (NO or SO2) enables the pollution measurement. The NO concentration can be expressed in terms of NOx as required by ambient laws.
External sensors are available for ambient parameters measurement: ambient relative humidity and temperature (T+RH%), ambient CO, to check and evaluate gas network leakage and natural gas leakage detector.
UniGas 3000+ can install a forth electrochemical sensor to monitor pollution. In this way you can measure simultaneously and using a single unit, NO/NOx and SO2 gas concentration.
The instruments are completed with a pressure (draught) sensor, an internal printer, an internal memory for storing data and a RS232 serial interface for configuration and data transfer from and to a PC.
Draft measurement is possible using the internal pressure sensor and the special gas sample probe.
The optional internal printer is impact type and the generated document is very legible and has a long time duration.
The internal standard memory may store up to 250 complete gas analysis divided by Tag. A PCMCIA memory card adapter can be installed to extend the standard memory.
The UniGas has a standard IR serial interface and an optional RS232 conversion module and a configuration PC software are available to configure the analyser.
Large LCD
Show three lines of parameters.
With alto Back light making it easy to see in low light conditions.
With a optional external remote temperature sensor for balance flue boiler gives you a more excrete efficiency measurement reading.


Unigas 3000 is complete with a build-
Customised header
The print out can be customised
Magnetic Rubber holster included
The Unigas 3000 comes with a Magnetic Holder. That will help keep the analyser in up right position.
Additional task such as CO room build up to comply with the BS7967,




Large back light graphic LCD can display up to 12 combustion parameters per page with either in numeric or graphic modes. This helps engineers quickly identify test results.

Up to 250 data sets can be manually stored during operation including addresses, boiler IDs and system numbers.

Dedicated task menu gives direct access to the desired function. Select the required test for instance FLOW/RETURN TEMP and with single key press, the analyser is ready.


The probe can remain positioned in the flue during the initialisation phase of the measurement
cells.
Instrument diagnosis provides you with information about
status of measuring cells along with rechargeable battery status and the last service.
UniGas 3000+ store up to 250 readings customised by boilers and customers. Using the
optional DBGas Windows
software package, you can organise and manage your inspection and maintenance activity.
Select your customer
and boiler details from PC and download to your UniGas. DBGas
software package incudes Gas Config Windows software, which allows to customise the
instruments configuration.








CO/CO2
ratio
O2
CO
CO
2
Efficiency
Tair
Tgas
Differential
pressure
Excess air

SO2

NO